Product Details:
Place of Origin: Germany
Brand Name: PF
Certification: ATEX
Model Number: KFD2-HMM-16
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiate
Packaging Details: carton
Delivery Time: stock
Payment Terms: T/T, Alipay, Paypal
Supply Ability: 100pcs per month
Detailed Product Description
Manufacture: Pepperl+Fuchs Model: KFD2-HMM-16
Power Consumption: Maximum 3 W Power Supply: 24 V DC
Control Elements: DIP-switch Interface Type: RS-485 , 2-wire Multidrop
Degree Of Protection: IP20 Shipping Weight: 1.5 Kg
Highlight:

pepperl fuchs kfd2 hmm 16

,

HART pepperl fuchs kfd2 hmm 16

,

kfd2 hmm 16 PEPPERL FUCHS

Product Details:
Manufacturer : Pepperl+Fuchs
Product No. : KFD2-HMM-16
Product Type : HART Multiplexer Master

 

Features:

  • 16-channel
  • 24 V DC supply (Power Rail)
  • HART field device input (revision 5 to 7)
  • Up to 15 KFD0-HMS-16 slave units can be connected
  • Up to SIL 3 acc. to IEC/EN 61508

Function

This HART Multiplexer Master operates up to 256 analog field instruments. The built-in slave unit in the HART master operates the first 16 field instruments. If more than 16 field instruments are required, up to 15 additional HART Multiplexer Slaves KFD0-HMS-16 can be connected.

The slave units are connected to the master with a 14-pin flat cable. The connector for the ribbon cable is found on the same housing side as the connectors for the interface and the power supply.

The analog signals are separately linked to a termination board via a 26-pin flat cable for each unit. Sixteen leads are reserved for the HART signal of the analog measurement circuits. The remaining 10 leads are sent to ground.

This unit is designed with removable terminals and can be connected to the Power Rail.

 

Technical data

1. Product Description
    HART Multiplexer Master
2. Functional safety related parameters
    Safety Integrity Level (SIL): SIL 3
3. Supply
    Connection: terminals 17+, 18-
    Rated voltage: 20 ... 32 V DC typical at 100 mA
    Power consumption: max. 3 W
4. HART signal channels (non-intrinsically safe)
    Conformity: HART field device input (revision 5 to 7)
    Connection: 26-pin flat cable for analog connections
                        14-pin flat cable for master-slave connection between KFD2-HMM-16 and KFD0-HMS-16
    Leakage current: < 3 µA at -20 ... 85 °C (-4 ... 185 °F)
    Terminating resistor: external 230 ... 500 Ω standard (up to 1000 Ω possible)
    Output voltage: ≥ 400 mV ss (with the terminator resistance specified above)
    Output resistance: 100 Ω or smaller, capacitive coupling
    Input impedance: according to HART specification
    Input voltage range: 0.08 ... 4 V ss ; typ. ± 5.2 V as local reference
5. Interface
    Transfer rate: 9600, 19200, or 38400 Bit/s (selectable with DIL switch (2 and 3) by the user)
    Type: RS-485 , 2-wire multidrop
    Address selection: One of 31 possible addresses selectable per DIL switch (4 ... 8)
6. Indicators/settings
    Control elements: DIP switch
    Configuration: via DIP switches
    Labeling: space for labeling at the front
7. Conformity
    Degree of protection: IEC 60529:2001
8. Ambient conditions
    Ambient temperature: -20 ... 60 °C (-4 ... 140 °F)
9. Mechanical specifications
    Degree of protection: IP20
    Connection: screw terminals
    Mass: approx. 250 g
    Dimensions: 40 x 107 x 115 mm (1.6 x 4.2 x 4.5 inch) (W x H x D) , housing type C1
       Height: 107 mm
       Width: 40 mm
       Depth: 115 mm
    Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001
 
HART Multiplexer Master PEPPERL FUCHS Kfd2 Hmm 16 0

 

Related Models:

KCD2-SCD-EX1 NBB5-18GM50-E2-V1
KCD2-STC-EX1.20 NBB8-18GM60-A2-V1
KFA6-DWB-EX1.D NBN3-F25F-E8-V1
KFA6-SR2-Ex2.W NBN40-U1K-N0
KFD0-CS-Ex1.50P NBN40-U4LK-N0
KFD0-HMS-16 NBVB15-U1.Z2
KFD0-RSH-1.4S.PS2 NCB5-18GM40-NO
KFD0-SD2-EX1.10100 NJ10-30GM-N-5M
KFD0-SD2-EX1.1045 NJ15-30GK-N
KFD2-UT2-1 NJ2-12GK-SN
KFD2-CD-1.32 NJ2-12GM-N
KFD2-CD-EX1.32 NJ4-12GK-SN
KFD2-HMM-16 NJ5-18GK-N
KFD2-SH-EX1.T NJ5-18GK-N-150
KFD2-SH-Ex1.T.OP NJ5-18GM-N
KFD2-SL2-EX2.B NJ8-18GK-N
KFD2-SR2-EX1.W RD0-FB-EX4
KFD2-SR2-Ex2.W RD0-FB-EX4.COM
KFD2-STC5-1.2O SC3,5-G-N0
KFD2-STC5-Ex1 SC3,5-G-N0-5M
KFD2-STC5-Ex1.H SC3,5-G-N0-6M
KFD2-UT2-1 SJ3,5-N
KFD2-VR4-EX1.26 SJ3,5-S1N
KFU8-UFC-1.D UPR-03
KFU8-UFT V15-G-2M
K-HM26-2M-261533 Z 787
NBB15-U1-E2 Z787.H
NBB15-U1-Z2 HIC2031

 
Company Introduction:
Achievers Automation Limited has more than 10 years experience in the market of Industrial Automation, specialized in reselling factory sealed Probe, Sensor, DCS,isolator barrier, HMI, PLC,Adapter,Profibus connector and cable from Brands as BENTLY NEVADA, Endress+Hauser, YOKOGAWA,MTL,Allen-Bradley, Pepperl+Fuchs,Rosemount, ASCO, Schneider, Lenze, Pro-face, Mitsubishi, Omron, Lenze, Delta, Honeywell, Siemens and etc. If you have any request, please do not hesitate to contact us.
 

FAQ of Achievers
Q:Are the Products Genuine OEM Units?
A: These items have been certified by Achievers Automation Limited to be genuine OEM Units obtained through OEM or independent third-party channels.
Q:How will you arrange shipment?
A: We can arrange shipment based on your request. We have cooperated forwader who can arrange shipment via FedEx, DHL,TNT with good price.
Q:What is the warranty of goods?
A: One-year Warranty.

 

Contact Details
Achievers Automation Limited

Contact Person: Caroline Chan

Tel: 13271919169

Send your inquiry directly to us (0 / 3000)