logo
Send Message
English
Achievers Automation Limited

Achievers makes all your needs Achievable!

Home ProductsPEPPERL FUCHS Isolated Barrier

KFD2-UT2-1 PEPPERL FUCHS Isolated Barrier Universal Temperature Converter Configurable By PACTware

I'm Online Chat Now

KFD2-UT2-1 PEPPERL FUCHS Isolated Barrier Universal Temperature Converter Configurable By PACTware

KFD2-UT2-1 PEPPERL FUCHS Isolated Barrier Universal Temperature Converter Configurable By PACTware
KFD2-UT2-1 PEPPERL FUCHS Isolated Barrier Universal Temperature Converter Configurable By PACTware KFD2-UT2-1 PEPPERL FUCHS Isolated Barrier Universal Temperature Converter Configurable By PACTware KFD2-UT2-1 PEPPERL FUCHS Isolated Barrier Universal Temperature Converter Configurable By PACTware

Large Image :  KFD2-UT2-1 PEPPERL FUCHS Isolated Barrier Universal Temperature Converter Configurable By PACTware

Product Details:
Place of Origin: Germany
Brand Name: PF
Certification: ATEX
Model Number: KFD2-UT2-1
Payment & Shipping Terms:
Minimum Order Quantity: 1 piece
Price: Negotiable
Packaging Details: 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2
Delivery Time: stock
Payment Terms: Alipay
Supply Ability: 100pcs per month
Detailed Product Description
Manufacturer: Pepperl+Fuchs Product No: KFD2-UT2-1
Rated Voltage: 20 ... 30 V DC Types Of Measuring: 2-, 3-, 4-wire Connection
Display Elements: LEDs Input Resistance: ≥ 1 MΩ (-100 ... 100 MV)
Voltage: Selectable Within The Range -100 ... 100 MV Power Consumption: Max. 0.98 W
Highlight:

KFD2-UT2-1 PEPPERL FUCHS Isolated Barrier

,

PEPPERL FUCHS Isolated Barrier KFD2-UT2-1

,

kfd2 ut2 1

PEPPERL FUCHS KFD2-UT2-1 Universal Temperature Converter Configurable By PACTware

 

Product Details:
Manufacturer : Pepperl+Fuchs
Product No. : KFD2-UT2-1
Product Type : Universal Temperature Converter

 

Features:
  • 1-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Thermocouple, RTD, potentiometer or voltage input
  • Current output 0/4 mA ... 20 mA
  • Sink or source mode
  • Configurable by PACTware
  • Line fault (LFD) and sensor burnout detection
  • Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511

Function
This signal conditioner provides the galvanic isolation between field circuits and control circuits.

The device converts the signal of a resistance thermometer, thermocouple, or potentiometer to a proportional output current.

The removable terminal block K-CJC-** is available as an accessory for internal cold junction compensation of thermocouples.

A fault is signalized by LEDs and a separate collective error message output.

The device is easily configured by the use of the PACTware configuration software.

For additional information, refer to the manual and www.pepperl-fuchs.com.

 

Technical Data

General specifications
Signal type Analog input
Functional safety related parameters
Safety Integrity Level (SIL) SIL 2
Supply
Connection terminals 14+, 15- or power feed module/Power Rail
Rated voltage 20 ... 30 V DC
Ripple within the supply tolerance
Power dissipation ≤ 0.98 W
Power consumption max. 0.98 W
Interface
Programming interface programming socket
Input
Connection side field side
Connection terminals 1, 2, 3, 4
RTD type Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995)
type Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94)
type Cu10, Cu50, Cu100 (P50353-92)
type Ni100 (DIN 43760)
  Measuring current approx. 200 µA with RTD
  Types of measuring 2-, 3-, 4-wire connection
  Lead resistance max. 50 Ω per line
  Measurement loop monitoring sensor breakage, sensor short-circuit
Thermocouples type B, E, J, K, N, R, S, T (IEC 584-1: 1995)
type L (DIN 43710: 1985)
type TXK, TXKH, TXA (P8.585-2001)
  Cold junction compensation external and internal
  Measurement loop monitoring sensor breakage
Potentiometer 0 ... 20 kΩ (2-wire connection), 0.8 ... 20 kΩ (3-wire connection)
Voltage selectable within the range -100 ... 100 mV
Input resistance ≥ 1 MΩ (-100 ... 100 mV)
Output
Connection side control side
Connection output I: terminal 7: source (-), sink (+), terminal 8: source (+), terminal 9: sink(-)
Output Analog current output
  Current range 0 ... 20 mA or 4 ... 20 mA
  Fault signal downscale 0 or 2 mA, upscale 21.5 mA (acc. NAMUR NE43)
  Source load 0 ... 550 Ω
open-circuit voltage ≤ 18 V
  Sink Voltage across terminals 5 ... 30 V. If the current is supplied from a source > 16.5 V,
series resistance of ≥ (V - 16.5)/0.0215 Ω is needed, where V is the source voltage.
The maximum value of the resistance is (V - 5)/0.0215 Ω.
Transfer characteristics
Deviation  
  After calibration Pt100: ± (0.06 % of measurement value in K + 0.1 % of span + 0.1 K (4-wire connection))
thermocouple: ± (0.05 % of measurement value in °C + 0.1 % of span + 1 K (1.2 K for types R and S)) , includes ± 0.8 K fault of the cold junction compensation (CJC)
mV: ± (50 µV + 0.1 % of span)
potentiometer: ± (0.05 % of full scale + 0.1 % of span, (excludes faults due to lead resistance))
  Influence of ambient temperature Pt100: ± (0.0015 % of measurement value in K + 0.006 % of span)/K ΔTamb*)
thermocouple: ± (0.02 K + 0.005 % of measurement value in °C + 0.006 % of span)/K ΔTamb*)), influence of cold junction compensation (CJC) included
mV: ± (0.01 % of measurement value + 0.006 % of span)/K ΔTamb*)
potentiometer: ± 0.006 % of span/K ΔTamb*)
*) ΔTamb = ambient temperature change referenced to 23 °C (296 K)
  Influence of supply voltage < 0.01 % of span
  Influence of load ≤ 0.001 % of output value per 100 Ω
Reaction time worst case value (sensor breakage and/or sensor short circuit detection enabled)
mV: 1 s, thermocouples with CJC: 1.1 s, thermocouples with fixed reference temperature: 1.1 s, 3- or 4-wire RTD: 920 ms, 2-wire RTD: 800 ms, Potentiometer: 2.05 s
Galvanic isolation
Input/Other circuits basic insulation according to IEC 61010-1, rated insulation voltage 300 Veff
Output/supply, programming input functional insulation, rated insulation voltage 50 V AC
There is no electrical isolation between the programming input and the supply.
The programming cable provides galvanic isolation so that ground loops are avoided.
Indicators/settings
Display elements LEDs
Configuration via PACTware
Labeling space for labeling at the front
Directive conformity
Electromagnetic compatibility  
  Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Conformity
Electromagnetic compatibility NE 21:2006
Degree of protection IEC 60529:2001
Ambient conditions
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protection IP20
Connection screw terminals
Mass approx. 130 g
Dimensions 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2
  Height 119 mm
  Width 20 mm
  Depth 115 mm
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
General information
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

 

KFD2-UT2-1 PEPPERL FUCHS Isolated Barrier Universal Temperature Converter Configurable By PACTware 0

 

KFD2-UT2-1 PEPPERL FUCHS Isolated Barrier Universal Temperature Converter Configurable By PACTware 1

 

Company Introduction:
Achievers Automation Limited has more than 10 years experience in the market of Industrial Automation, specialized in reselling factory sealed Probe, Sensor, DCS,isolator barrier, HMI, PLC,Adapter,Profibus connector and cable from Brands as BENTLY NEVADA, Endress+Hauser, YOKOGAWA,MTL,Allen-Bradley, Pepperl+Fuchs,Rosemount, ASCO, Schneider, Lenze, Pro-face, Mitsubishi, Omron, Lenze, Delta, Honeywell, Siemens and etc. If you have any request, please do not hesitate to contact us.
 

FAQ of Achievers
Q:Are the Products Genuine OEM Units?
A: These items have been certified by Achievers Automation Limited to be genuine OEM Units obtained through OEM or independent third-party channels.
Q:How will you arrange shipment?
A: We can arrange shipment based on your request. We have cooperated forwader who can arrange shipment via FedEx, DHL,TNT with good price.
Q:What is the warranty of goods?
A: One-year Warranty.

Contact Details
Achievers Automation Limited

Contact Person: Caroline Chan

Tel: 13271919169

Send your inquiry directly to us (0 / 3000)