Product Details:
Place of Origin: UK/China
Brand Name: MTL
Certification: HART
Model Number: MTL5546
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: carton
Delivery Time: Negotiable
Payment Terms: T/T, Alipay, Paypal
Supply Ability: 1000pcs per week
Detailed Product Description
Manufacturer: MTL Instruments Product No.: MTL5546
Product Type: Isolating Driver Working Range: 4 To 20mA
Digital Signal Bandwidth: 500Hz To 10kHz Output Resistance: > 1M O
Temperature Drift: < 1.0µA/°C Shipping Weight: 1.5 Kg
Highlight:

MTL isolating driver

,

isolating driver MTL5546

,

MTL5546

MTL5546 MTL Instruments Isolating Driver

 

The MTL5546 accepts a 4/20mA floating signal from a safe-area
controller to drive a current/pressure converter (or any other load up
to 800Ω) in a hazardous area. For smart valve positioners, the module
also permits bi-directional transmission of digital communication
signals so that the device can be interrogated either from the operator
station or by a hand-held communicator. Process controllers with a
readback facility can detect open or short circuits in the field wiring:
if these occur, the current taken into the terminals drops to a preset
level.

 

SPECIFICATION
See also common specification
• Number of channels
     One
• Location of I/P converter
     Zone 0, IIC, T4–6 hazardous area if suitably certified
     Div. 1, Group A, hazardous location
• Working range
     4 to 20mA
• Digital signal bandwidth
     500Hz to 10kHz
• Maximum load resistance
     800Ω (16V at 20mA)
• Minimum load resistance
     90Ω (short-circuit detection at < 50Ω)
• Output resistance
     > 1MΩ
• Under/over range capability
     Under range = 1mA
     Over range = 24mA (load ≤ 520Ω)
• Input and output circuit ripple
     < 40µA peak-to-peak
• Transfer accuracy at 20°C
     Better than 20µA
• Temperature drift
     < 1.0µA/°C
• Input characteristics
     < 6.0V with the field wiring intact
     < 0.9mA with the field wiring open or short-circuit
• Response time
     Settles within 200µA of final value within 100ms
• Communications supported
     HART®
• LED indicator
     Green: power indication
• Maximum current consumption (with 20mA signals into 250Ω load)
     35mA at 24V dc
• Power dissipation within unit (with 20mA signals into 250Ω load)
     0.8W at 24V
• Safety description
     Vo=28V Io=93mA Po=651mW Um = 253V rms or dc

 

MTL5546 MTL Isolating Driver For 4–20mA HART® Valve Positioners  With Line Fault Detection 0

 

Related Models:

HCU16 MTL5521
HCU3700 MTL5522
HM64RIB20-1.0 MTL5531
HM64RIB20-1.5 MTL5532
HMM64 MTL5541
HMRIB16-1.0 MTL5541S
HMS64 MTL5544
HTP-SC32 MTL5544D
MTL4044D MTL5546
MTL4511 MTL5546Y
MTL4516 MTL5561
MTL4516C MTL5573
MTL4521 MTL5575
MTL4541 MTL5582B
MTL4541 MTL7728+
MTL4544 MTL7756AC
MTL4544D MTL7760AC
MTL4546Y MTL7761PAC
MTL4549Y MTL7765AC
MTL4573 MTL7787+
MTL4575 MTL7787P+
MTL4646Y MTLCPS16
MTL4850 NJ5-18GK-N
MTL4851 SD150X
MTL4852 SD32
MTL5018 SD32X
MTL5032 SDRTD
MTL5042 SLP32D
MTL5044 TP48-3-I-NDI
MTL5049 TP48-3-N-NDI
MTL5511 TP48-4-I-NDI
MTL5514D TP48-4-N-NDI
MTL5516 TP48-N-NDI
MTL5516C ZB24571

 

Company Introduction:
Achievers Automation Limited has more than 10 years experience in the market of Industrial Automation, specialized in reselling factory sealed Probe, Sensor, DCS,isolator barrier, HMI, PLC,Adapter,Profibus connector and cable from Brands as BENTLY NEVADA, Endress+Hauser, YOKOGAWA,MTL,Allen-Bradley, Pepperl+Fuchs,Rosemount, ASCO, Schneider, Lenze, Pro-face, Mitsubishi, Omron, Lenze, Delta, Honeywell, Siemens and etc. If you have any request, please do not hesitate to contact us.

FAQ of Achievers
Q:Are the Products Genuine OEM Units?
A: These items have been certified by Achievers Automation Limited to be genuine OEM Units obtained through OEM or independent third-party channels.
Q:How will you arrange shipment?
A: We can arrange shipment based on your request. We have cooperated forwader who can arrange shipment via FedEx, DHL,TNT with good price.
Q:What is the warranty of goods?
A: One-year Warranty.

Contact Details
Achievers Automation Limited

Contact Person: Caroline Chan

Tel: 13271919169

Send your inquiry directly to us (0 / 3000)