logo
Send Message
English
Achievers Automation Limited

Achievers makes all your needs Achievable!

Home ProductsPEPPERL FUCHS Isolated Barrier

KFD2-SR2-EX1.W PEPPERL FUCHS Isolated Barrier

I'm Online Chat Now

KFD2-SR2-EX1.W PEPPERL FUCHS Isolated Barrier

KFD2-SR2-EX1.W PEPPERL FUCHS Isolated Barrier
KFD2-SR2-EX1.W PEPPERL FUCHS Isolated Barrier KFD2-SR2-EX1.W PEPPERL FUCHS Isolated Barrier KFD2-SR2-EX1.W PEPPERL FUCHS Isolated Barrier

Large Image :  KFD2-SR2-EX1.W PEPPERL FUCHS Isolated Barrier

Product Details:
Place of Origin: Germany
Brand Name: PF
Certification: ATEX
Model Number: KFD2-SR2-EX1.W
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiate
Packaging Details: carton
Delivery Time: stock
Payment Terms: T/T, Alipay, Paypal
Supply Ability: 100pcs per month
Detailed Product Description
Manufacture: Pepperl+Fuchs Model: KFD2-SR2-EX1.W
Rated Voltage: 20 ... 30 V DC Output: Relay
Dimensions: 2 Cm X 11.8 Cm X 11.5 Cm Ambient Temperature: -40 ... 70 °C (-40 ... 158 °F)
Rated Current: ≤ 35 MA Power Dissipation: ≤ 0.7 W
Highlight:

KFD2-SR2-EX1.W PEPPERL FUCHS Isolated Barrier

,

PEPPERL FUCHS Isolated Barrier KFD2-SR2-EX1.W

,

pepperl fuchs kfd2 sr2 ex1 w

Product Details:
Manufacturer : Pepperl+Fuchs
Product No. : KFD2-SR2-EX1.W
Product Type : Transformer Isolated Barriers

 

Features:

  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • Relay contact output
  • Line fault detection (LFD)
  • Reversible mode of operation
  • Up to SIL 2 (SC 3) acc. to IEC/EN 61508

Function

This isolated barrier is used for intrinsic safety applications.

The device transfers digital signals from NAMUR sensors or dry contacts from the hazardous area to the non-hazardous area.

The proximity sensor or the mechanical contact controls the control side load for a relay contact output. The device output changes the state when the input signal changes the state.

Via switches the mode of operation can be reversed and the line fault detection can be switched off.

During a fault condition, the relay reverts to its de-energized state and the LEDs indicate the fault according to NAMUR NE 44.

If the device is operated via Power Rail, additionally a collective error message is available.

 

Technical data

1. General specifications
    Signal type: Digital Input
2. Functional safety related parameters
    Safety Integrity Level (SIL): SIL 2
    Systematic capability (SC): SC 3
3. Supply
    Connection: Power Rail or terminals 14+, 15-
    Rated voltage: 19 ... 30 V DC
    Ripple: ≤ 10 %
    Rated current: ≤ 35 mA
    Power dissipation: ≤ 0.7 W
    Power consumption: ≤ 0.7 W
4. Input
    Connection side: field side
    Connection: terminals 1+, 2+, 3-
    Rated values: acc. to EN 60947-5-6 (NAMUR)
    Open circuit voltage/short-circuit current: approx. 8 V DC / approx. 8 mA
    Switching point/switching hysteresis: 1.2 ... 2.1 mA / approx. 0.2 mA
    Line fault detection: breakage I ≤ 0.1 mA , short-circuit I > 6 mA
    Pulse/Pause ratio: min. 20 ms / min. 20 ms
5. Output
    Connection side: control side
    Connection: terminals 7, 8, 9
    Output: signal ; relay
    Contact loading: 250 V AC/2 A/cos φ > 0.75; 126.5 V AC/4 A/cos φ > 0.75; 40 V DC/2 A resistive load
    Minimum switch current: 2 mA / 24 V DC
    Energized/De-energized delay: approx. 20 ms / approx. 20 ms
    Mechanical life: 107 switching cycles
    Collective error message: Power Rail
6. Transfer characteristics
    Switching frequency: < 10 Hz
7. Galvanic isolation
    Input/Output: reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
    Input/power supply: reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
    Output/power supply: reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
8. Indicators/settings
    Display elements: LEDs
    Control elements: DIP switch
    Configuration: via DIP switches
    Labeling: space for labeling at the front
9. Conformity
    Electromagnetic compatibility: NE 21:2017 , EN 61326-3-1:2017 , EN IEC 61326-3-2:2018
    Degree of protection: IEC 60529:1989+A1:1999+A2:2013
    Functional safety: IEC/EN 61508:2010
    Input: EN 60947-5-6:2000
10. Ambient conditions
    Ambient temperature: -40 ... 70 °C (-40 ... 158 °F)
11. Mechanical specifications
    Degree of protection: IP20
    Connection: screw terminals
    Mass: approx. 150 g
    Dimensions: 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2
       Height: 119 mm
       Width: 20 mm
       Depth: 115 mm
    Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001
 
KFD2-SR2-EX1.W PEPPERL FUCHS Isolated Barrier 0

 

Related Models:

KCD2-SCD-EX1 NBB5-18GM50-E2-V1
KCD2-STC-EX1.20 NBB8-18GM60-A2-V1
KFA6-DWB-EX1.D NBN3-F25F-E8-V1
KFA6-SR2-Ex2.W NBN40-U1K-N0
KFD0-CS-Ex1.50P NBN40-U4LK-N0
KFD0-HMS-16 NBVB15-U1.Z2
KFD0-RSH-1.4S.PS2 NCB5-18GM40-NO
KFD0-SD2-EX1.10100 NJ10-30GM-N-5M
KFD0-SD2-EX1.1045 NJ15-30GK-N
KFD2-UT2-1 NJ2-12GK-SN
KFD2-CD-1.32 NJ2-12GM-N
KFD2-CD-EX1.32 NJ4-12GK-SN
KFD2-HMM-16 NJ5-18GK-N
KFD2-SH-EX1.T NJ5-18GK-N-150
KFD2-SH-Ex1.T.OP NJ5-18GM-N
KFD2-SL2-EX2.B NJ8-18GK-N
KFD2-SR2-EX1.W RD0-FB-EX4
KFD2-SR2-Ex2.W RD0-FB-EX4.COM
KFD2-STC5-1.2O SC3,5-G-N0
KFD2-STC5-Ex1 SC3,5-G-N0-5M
KFD2-STC5-Ex1.H SC3,5-G-N0-6M
KFD2-UT2-1 SJ3,5-N
KFD2-VR4-EX1.26 SJ3,5-S1N
KFU8-UFC-1.D UPR-03
KFU8-UFT V15-G-2M
K-HM26-2M-261533 Z 787
NBB15-U1-E2 Z787.H
NBB15-U1-Z2 HIC2031

 
Company Introduction:
Achievers Automation Limited has more than 10 years experience in the market of Industrial Automation, specialized in reselling factory sealed Probe, Sensor, DCS,isolator barrier, HMI, PLC,Adapter,Profibus connector and cable from Brands as BENTLY NEVADA, Endress+Hauser, YOKOGAWA,MTL,Allen-Bradley, Pepperl+Fuchs,Rosemount, ASCO, Schneider, Lenze, Pro-face, Mitsubishi, Omron, Lenze, Delta, Honeywell, Siemens and etc. If you have any request, please do not hesitate to contact us.
 

FAQ of Achievers
Q:Are the Products Genuine OEM Units?
A: These items have been certified by Achievers Automation Limited to be genuine OEM Units obtained through OEM or independent third-party channels.
Q:How will you arrange shipment?
A: We can arrange shipment based on your request. We have cooperated forwader who can arrange shipment via FedEx, DHL,TNT with good price.
Q:What is the warranty of goods?
A: One-year Warranty.

 

Contact Details
Achievers Automation Limited

Contact Person: Caroline Chan

Tel: 13271919169

Send your inquiry directly to us (0 / 3000)